Choose which end gets the hex coupling-nut pocket. The round shaft/stud hole is automatically placed on the opposite end.
The default estimator now uses both measured 45 mm OD / 3 mm pitch coil pairs. Between 18 and 23 turns it interpolates the correction factor. Outside that range it clamps to the nearest measured factor. If you change diameter or pitch, Wheeler's formula provides the geometry scaling.
Leave the override blank for the measured two-point model. Use an override only when you deliberately want one fixed multiplier for every turn count.
The calibration improves the turn-count estimate, but it does not replace measuring the finished wound coil. Different wire, diameter, pitch and hardware can still shift inductance.
Ready.
The target µH calculation is an estimate. The default model combines Wheeler's single-layer air-core formula with your measured 18-turn and 23-turn correction factors. Different diameters, wire, spacing, hardware and winding technique can shift the result. Measure each finished coil and add new measurements to future calibration updates.